Reference module. Benewake TF350 (rangefinder module): 905 nm, max range 350 m (indoor, no ambient light, 90% reflectivity (outdoor @100Klux: 300 m @90%)), interface UART/CAN/RS-485/RS-232, 224 g. Source.
Below are the 9 catalogued modules whose published maximum range is between 0.5× and 2.5× of the Benewake TF350, ordered by how close they are in range, then weight, interface and wavelength class (no manufacturer is ranked by preference). None of them is a drop-in replacement unless the protocol, connector, supply voltage and mounting match; check the linked datasheet. Ranges are quoted by each maker under its own target condition, so compare the condition column too.
| Brand | Model | nm | Max range | Range condition | Min m | Accuracy | Rate | Interface | Weight g | USD (1 pc) | Open-source driver | Source | Compared with reference |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Benewake | TF350 | 905 | 350 m | indoor, no ambient light, 90% reflectivity (outdoor @100Klux: 300 m @90%) | 0.2 | ±10 cm (within 10 m); 1% (10 m and further) | 1 ~ 1000 Hz | UART, CAN, RS-232, RS-485 | 224 | ArduPilot AP_RangeFinder | source 2026-11-17 | range ×1; weight ×1; shared interface: CAN/RS-232/RS-485/UART | |
| Benewake | TFA300 | 905 | 270 m | 90% reflectivity, 100 KLux (150 m @ 30%, 90 m @ 10%, same conditions) | 0.1 | ±10 cm (<10 m); 1% (≥10 m) | 1-10,000 Hz configurable (default 50 Hz) | UART, CAN (switchable by command) | 34.5 | source 2026-11-17 | range ×0.77; weight ×0.15; shared interface: CAN/UART | ||
| ERDI | LRF300H | 905 | 300 m | 0.05–300 m (90% reflectivity); 0.05–100 m (10% reflectivity) (The two source values remain bound to their stated target reflectivity.) | 0.05 | ±10 cm (<10 m); 1% (≥10 m) | 1 kHz or 50 Hz (automatically switched to match reflected-signal intensity) | UART, IIC | 20 | 280 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×0.86; weight ×0.089; shared interface: UART |
| Benewake | TF03-100/180 | 905 | 180 m | TF03-180: 180 m @ 90% ref.; TF03-100: 100 m @ 90% ref. (70 m / 40 m @ 10%) | 0.1 | ±10 cm (<10 m); 1% (≥10 m) | 1 ~ 9800 Hz | UART, CAN, RS-232, RS-485 | 86 | ArduPilot AP_RangeFinder | source 2026-11-17 | range ×0.51; weight ×0.38; shared interface: CAN/RS-232/RS-485/UART | |
| Benewake | TFA300-L | 905 | 290 m | 90% reflectivity, 100 KLux (170 m @ 30%, 100 m @ 10%, same conditions) | 0.1 | ±10 cm (<10 m); 1% (≥10 m) | 1-10,000 Hz configurable (default 50 Hz) | UART, CAN (switchable by command) | 10.5 | source 2026-11-17 | range ×0.83; weight ×0.047; shared interface: CAN/UART | ||
| LightWare | SF30/D | 905 | 200 m | 70% reflectivity | 0.2 | 39 to 20 000 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 30 | 459 | source 2026-11-06 | range ×0.57; weight ×0.13; shared interface: UART | ||
| LightWare | GRF-250 | 905 | 250 m | at 50 Hz update rate, 40% albedo, 10 km visibility, 1.4 m x 1.4 m target size | 0.2 | ± 50 cm (1 sigma) | 1 to 50 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 10.7 | 399 | grf250-api (GitHub, LightWare, MIT), ArduPilot AP_RangeFinder | source 2026-11-06 | range ×0.71; weight ×0.048; shared interface: UART |
| ERDI | LRF600H | 905 | 600 m | 0.05–600 m (90% reflectivity); 0.05–200 m (10% reflectivity) (The two source values remain bound to their stated target reflectivity.) | 0.05 | ±10 cm (<10 m); 1% (≥10 m) | 1 kHz or 50 Hz (automatically switched to match reflected-signal intensity) | UART/IIC | 20 | 350 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×1.7; weight ×0.089; shared interface: UART |
| LightWare | GRF-500 | 905 | 500 m | at 5 Hz update rate, 40% albedo, 23 km visibility, 4 m x 4 m target size | 0.2 | ± 50 cm (1 sigma) | 0.5 to 10 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 10.7 | 459 | grf-500-api (GitHub, LightWare, MIT-0), ArduPilot AP_RangeFinder | source 2026-11-06 | range ×1.4; weight ×0.048; shared interface: UART |
| ERDI | LRF200H | 905 | 200 m | 0.05–200 m (90% reflectivity); 0.05–70 m (10% reflectivity) (The two source values remain bound to their stated target reflectivity.) | 0.05 | ±10 cm (<10 m); 1% (≥10 m) | 20 Hz-10 kHz (default: 1 kHz) | UART, IIC | 20 | 250 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×0.57; weight ×0.089; shared interface: UART |
Missing a module? Add it in a pull request with the manufacturer source link.