Reference module. LightWare SF30/D (rangefinder module): 905 nm, max range 200 m (70% reflectivity), interface UART/I2C/USB, 30 g, public price $459. Source.
Below are the 16 catalogued modules whose published maximum range is between 0.5× and 2.5× of the LightWare SF30/D, ordered by how close they are in range, then weight, interface and wavelength class (no manufacturer is ranked by preference). None of them is a drop-in replacement unless the protocol, connector, supply voltage and mounting match; check the linked datasheet. Ranges are quoted by each maker under its own target condition, so compare the condition column too.
| Brand | Model | nm | Max range | Range condition | Min m | Accuracy | Rate | Interface | Weight g | USD (1 pc) | Open-source driver | Source | Compared with reference |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LightWare | SF30/D | 905 | 200 m | 70% reflectivity | 0.2 | 39 to 20 000 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 30 | 459 | source 2026-11-06 | range ×1; weight ×1; shared interface: I2C/UART/USB | ||
| ERDI | LRF200H | 905 | 200 m | 0.05–200 m (90% reflectivity); 0.05–70 m (10% reflectivity) (The two source values remain bound to their stated target reflectivity.) | 0.05 | ±10 cm (<10 m); 1% (≥10 m) | 20 Hz-10 kHz (default: 1 kHz) | UART, IIC | 20 | 250 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×1; weight ×0.67; shared interface: I2C/UART |
| Benewake | TFA300 | 905 | 270 m | 90% reflectivity, 100 KLux (150 m @ 30%, 90 m @ 10%, same conditions) | 0.1 | ±10 cm (<10 m); 1% (≥10 m) | 1-10,000 Hz configurable (default 50 Hz) | UART, CAN (switchable by command) | 34.5 | source 2026-11-17 | range ×1.4; weight ×1.1; shared interface: UART | ||
| JRT | ETYS-HF-2 | 905 | 150 m | >=150 m (conventional natural large targets) | 0.1 | <=0.1m (0.1-2m); 5%×L (>2m) | 20Hz-10KHz | RS422/TTL (baud 19200-921600 bps) | 45 | 565 | source 2026-11-17 | range ×0.75; weight ×1.5; shared interface: UART | |
| Benewake | TF03-100/180 | 905 | 180 m | TF03-180: 180 m @ 90% ref.; TF03-100: 100 m @ 90% ref. (70 m / 40 m @ 10%) | 0.1 | ±10 cm (<10 m); 1% (≥10 m) | 1 ~ 9800 Hz | UART, CAN, RS-232, RS-485 | 86 | ArduPilot AP_RangeFinder | source 2026-11-17 | range ×0.9; weight ×2.9; shared interface: UART | |
| ERDI | LRF300H | 905 | 300 m | 0.05–300 m (90% reflectivity); 0.05–100 m (10% reflectivity) (The two source values remain bound to their stated target reflectivity.) | 0.05 | ±10 cm (<10 m); 1% (≥10 m) | 1 kHz or 50 Hz (automatically switched to match reflected-signal intensity) | UART, IIC | 20 | 280 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×1.5; weight ×0.67; shared interface: I2C/UART |
| LightWare | GRF-250 | 905 | 250 m | at 50 Hz update rate, 40% albedo, 10 km visibility, 1.4 m x 1.4 m target size | 0.2 | ± 50 cm (1 sigma) | 1 to 50 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 10.7 | 399 | grf250-api (GitHub, LightWare, MIT), ArduPilot AP_RangeFinder | source 2026-11-06 | range ×1.2; weight ×0.36; shared interface: I2C/UART/USB |
| Benewake | TFA300-L | 905 | 290 m | 90% reflectivity, 100 KLux (170 m @ 30%, 100 m @ 10%, same conditions) | 0.1 | ±10 cm (<10 m); 1% (≥10 m) | 1-10,000 Hz configurable (default 50 Hz) | UART, CAN (switchable by command) | 10.5 | source 2026-11-17 | range ×1.4; weight ×0.35; shared interface: UART | ||
| LightWare | SF30/C | 905 | 100 m | 70% reflectivity | 0.2 | 39 to 20 000 readings per second | USB, Serial UART (3.3 V TTL, 5 V tolerant) | 30 | 349 | source 2026-11-06 | range ×0.5; weight ×1; shared interface: UART/USB | ||
| ERDI | LRF100H | 905 | 100 m | 0.05–100 m (90% reflectivity); 0.05–30 m (10% reflectivity) (The two source values remain bound to their stated target reflectivity.) | 0.05 | ±10 cm (<10 m); 1% (≥10 m) | 20 Hz-10 kHz (default: 1 kHz) | UART, IIC | 20 | 200 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×0.5; weight ×0.67; shared interface: I2C/UART |
| LightWare | LW20/C | 905 | 100 m | 70% reflectivity | 0.2 | 48 to 5 000 readings per second | Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 19.5 | 349 | LW20-Api (GitHub, LightWare-Optoelectronics), ArduPilot AP_RangeFinder | source 2026-11-06 | range ×0.5; weight ×0.65; shared interface: I2C/UART | |
| LightWare | LW20/HA | 100 m | 70% reflectivity | 0.2 | Better than 1cm over 100m | 48 to 1 250 readings per second | Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 19.5 | 389 | LW20-Api (GitHub, LightWare-Optoelectronics), ArduPilot AP_RangeFinder | source 2026-11-17 | range ×0.5; weight ×0.65; shared interface: I2C/UART | |
| Benewake | TFA170-L | 170 m | 0.1 | 1 ~ 1000 Hz | RS-232 | 10 | source 2026-11-06 | range ×0.85; weight ×0.33; different interface | |||||
| LightWare | SF20/C | 905 | 100 m | 70% reflectivity | 0.2 | 48 to 5 000 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 7.5 | 319 | LW20-Api (GitHub, LightWare-Optoelectronics), ArduPilot AP_RangeFinder | source 2026-11-06 | range ×0.5; weight ×0.25; shared interface: I2C/UART/USB | |
| Benewake | TF350 | 905 | 350 m | indoor, no ambient light, 90% reflectivity (outdoor @100Klux: 300 m @90%) | 0.2 | ±10 cm (within 10 m); 1% (10 m and further) | 1 ~ 1000 Hz | UART, CAN, RS-232, RS-485 | 224 | ArduPilot AP_RangeFinder | source 2026-11-17 | range ×1.8; weight ×7.5; shared interface: UART | |
| LightWare | GRF-500 | 905 | 500 m | at 5 Hz update rate, 40% albedo, 23 km visibility, 4 m x 4 m target size | 0.2 | ± 50 cm (1 sigma) | 0.5 to 10 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 10.7 | 459 | grf-500-api (GitHub, LightWare, MIT-0), ArduPilot AP_RangeFinder | source 2026-11-06 | range ×2.5; weight ×0.36; shared interface: I2C/UART/USB |
| LightWare | SF20/HA | 100 m | 70% reflectivity | 0.2 | Better than 1cm over 100m | 48 to 1 250 readings per second | USB, Serial UART and I2C (3.3 V TTL, 5 V tolerant) | 7.5 | 359 | LW20-Api (GitHub, LightWare-Optoelectronics), ArduPilot AP_RangeFinder | source 2026-11-17 | range ×0.5; weight ×0.25; shared interface: I2C/UART/USB |
Modules with more than 2.5× the range whose public single-unit price is at or below $459. Only makers that publish prices can appear here.
| Brand | Model | nm | Max range | Range condition | Min m | Accuracy | Rate | Interface | Weight g | USD (1 pc) | Open-source driver | Source | Compared with reference |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ERDI | LRF600H | 905 | 600 m | 0.05–600 m (90% reflectivity); 0.05–200 m (10% reflectivity) (The two source values remain bound to their stated target reflectivity.) | 0.05 | ±10 cm (<10 m); 1% (≥10 m) | 1 kHz or 50 Hz (automatically switched to match reflected-signal intensity) | UART/IIC | 20 | 350 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×3; weight ×0.67; shared interface: I2C/UART |
| ERDI | LR1000E2 | 905 | 1 km | 4–1,000 m (Standard range; actual reach depends on target and environment.) | 4 | ±1 m (D ≤ 400 m); ±(1 + 0.001D) m (D > 400 m) (Whiteboard target, 90% reflectivity: 2.3 × 2.3 m for the first distance interval; 2.3 × 4.6 m for the second.) | 3–10 Hz (adaptive) | UART-TTL | 10 | 80 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×5; weight ×0.33; shared interface: UART |
| ERDI | LR1000E4 | 905 | 1 km | 4–1,000 m (Standard range; actual reach depends on target and environment.) | 4 | ±1 m (D ≤ 400 m); ±(1 + 0.001D) m (D > 400 m) (Whiteboard target, 90% reflectivity: 2.3 × 2.3 m for the first distance interval; 2.3 × 4.6 m for the second.) | 3–10 Hz (adaptive) | UART-TTL | 10 | 80 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×5; weight ×0.33; shared interface: UART |
| ERDI | SPD1200N3 | 905 | 1 km | 3–1,000 m (Building target; visibility ≥10 km; humidity ≤60%) | 3 | ±0.5 m at d ≤100 m; ±(0.5 m + 0.00075d) for 100 m < d <1,000 m (d is distance in meters; no additional endpoint accuracy inferred) | 2.5–15 Hz | UART, 3.3 V TTL; customizable | 6 | 94.5 | source 2026-11-12 | range ×5; weight ×0.2; shared interface: UART | |
| ERDI | LR1000D23 | 905 | 1 km | White building: 4 m – 1,000 m (max. 1,200 m at night); vegetation ≥ 750 m (The white-building, vegetation and night-time figures are separate source test cases. | 4 | δ ≤ 100 cm, 5 m ≤ d < 1000 m¹) (Standard version: ±1 m) (Target and ambient conditions not stated) | 3 Hz – 12 Hz (customizable) | UART-TTL, customizable | 20 | 110 | source 2026-11-12 | range ×5; weight ×0.67; shared interface: UART | |
| JRT | PTGL-12X-1 | 905 | 1.2 km | Max: >=1200 m @ 70% reflectivity (building target, visibility >= 6 km); Min: 0.2 m @ 90% reflectivity | 0.2 | d <= 100 m: ±0.3 m; d > 100 m: ±(0.4 + 0.006 × d) m | 2 Hz – 15 Hz (Adaptive) | UART (TTL_3.3V) | 6 | 49 | source 2026-11-17 | range ×6; weight ×0.2; shared interface: UART | |
| JRT | PTGL2-12X-1 | 905 | 1.2 km | Max: >=1200 m @ 70% reflectivity (visibility >=6km); Min: 0.2 m @ 90% reflectivity | 0.2 | d <= 100m: ±0.3m; d >= 100m: ±(0.3 + 0.0007 × D) | 2Hz–30Hz (adaptive) | UART (TTL 3.3V) | 6 | 49 | source 2026-11-17 | range ×6; weight ×0.2; shared interface: UART | |
| JRT | PTGC-12X-2 | 905 | 1.2 km | 5 | 5≤L≤100m: ±0.7m; L>100m: ±(0.7+L*0.4%)m | 1-3Hz | UART-TTL (3.3V) | 22 | 63 | source 2026-11-17 | range ×6; weight ×0.73; shared interface: UART | ||
| JRT | PTGS-12X-1 | 905 | 1.2 km | 5 | 5≤L≤100m: ±0.7m; L>100m: ±(0.7+L*0.4%)m (page prints '±(0.7 L*0.4%)m', operator missing) | 1-3Hz | UART-TTL (3.3V) | 12 | 63 | source 2026-11-17 | range ×6; weight ×0.4; shared interface: UART | ||
| ERDI | LR1200E2 | 905 | 1.2 km | 4–1,200 m (Standard range; actual reach depends on target and environment.) | 4 | ±1 m (6 m ≤ D < 500 m); ±(0.5 m + 0.001D) (500 m ≤ D ≤ 1,200 m) (Whiteboard target, 90% reflectivity: 2.3 × 2.3 m for the first distance interval; 2.3 × 4.6 m for the second.) | 2–10 Hz (adaptive) | UART-TTL | 10 | 90 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×6; weight ×0.33; shared interface: UART |
| ERDI | LR1200E4 | 905 | 1.2 km | 4–1,200 m (Standard range; actual reach depends on target and environment.) | 4 | ±1 m (D ≤ 400 m); ±(1 + 0.001D) m (D > 400 m) (Target and ambient conditions not stated) | 2–10 Hz (adaptive) | UART-TTL | 10 | 90 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×6; weight ×0.33; shared interface: UART |
| ERDI | LRF1200A1 | 905 | 1.2 km | 5–1,200 m (Building target; the source table gives ≥5–1200 m.) | 5 | ±1 m (5 m ≤ L ≤ 100 m); ±(1 + 0.004L) m (L > 100 m) (L is distance in meters.) | 1–3 Hz | UART, 3.3 V TTL | 18 | 90 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×6; weight ×0.6; shared interface: UART |
| ERDI | SPD1200N0 | 905 | 1.2 km | Catalog range 0.2–1,200 m. A 1,500 m night-time figure appears in the source under special conditions and is not a guaranteed range. (SPD1200N0 controlled sourc | 0.2 | ±0.3 m (D ≤100 m); ±0.3 m + D × 0.7‰ (100 m < D <1,200 m) (SPD1200N0 controlled source technical table) | 2–15 Hz or 4–15 Hz, adaptive (SPD1200N0 controlled source technical table; both alternatives appear in the same formal source row) | UART-TTL (customizable) | 5 | 90 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×6; weight ×0.17; shared interface: UART |
| ERDI | SPD1200N2 | 905 | 1.2 km | Catalog range 0.2–1,200 m. A 1,500 m night-time figure appears in the source under special conditions and is not a guaranteed range. (SPD1200N2 controlled sourc | 0.2 | ±0.3 m (D ≤100 m); ±0.3 m + D × 0.7‰ (100 m < D <1,200 m) (SPD1200N2 controlled source technical table) | 2–15 Hz or 4–15 Hz, adaptive | UART-TTL (customizable) | 5 | 90 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×6; weight ×0.17; shared interface: UART |
| ERDI | SPD1200N4 | 905 | 1.2 km | Catalog range 0.2–1,200 m. A 1,500 m night-time figure appears in the source under special conditions and is not a guaranteed range. (SPD1200N4 controlled sourc | 0.2 | ±0.3 m (D ≤100 m); ±0.3 m + D × 0.7‰ (100 m < D <1,200 m) (SPD1200N4 controlled source technical table) | 2–15 Hz or 4–15 Hz, adaptive (SPD1200N4 controlled source technical table; both alternatives appear in the same formal source row) | UART-TTL (customizable) | 5 | 90 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×6; weight ×0.17; shared interface: UART |
| ERDI | LR1200D23 | 905 | 1.2 km | 4 m – 1,200 m (max. 1,200 m) (Target and ambient conditions not stated) | 4 | δ ≤ ±1 m, 4 m ≤ d < 1000 m¹) (Standard version: ±1 m) (Target and ambient conditions not stated) | 2–10 Hz | UART - TTL, customizable | 20 | 130 | source 2026-11-12 | range ×6; weight ×0.67; shared interface: UART | |
| ERDI | SPD1200S2 | 905 | 1.2 km | Catalog range: 0.2–1,200 m. Sources also report a 1,500 m night-time maximum under special conditions; it is not a guaranteed range. (Strong sunlight or low vis | 0.2 | ±0.3m (≤400m)±0.5m + d × 0.1% (400m<d<1,200m) | 4Hz~15Hz Adaptive | UART-TTL, Customizable | 10 | 150 | source 2026-11-12 | range ×6; weight ×0.33; shared interface: UART | |
| ERDI | SPD1200Z2 | 905 | 1.2 km | Catalog range: 0.2–1,200 m; strong sunlight or low visibility may reduce range. Sources also list a 1,500 m night-time maximum under special conditions; it is n | 0.2 | ±0.2 m (d ≤ 200 m); ±0.5 m (d ≤ 400 m); ±(0.5 m + 0.001d) (400 m < d < 1,200 m); d is distance in metres | 2–20 Hz adaptive | UART-TTL, Customizable | 6 | 150 | source 2026-11-12 | range ×6; weight ×0.2; shared interface: UART | |
| ERDI | SPD1200ZG | 905 | 1.2 km | 0.1–1,200 m (Visibility ≥10 km; humidity ≤60%; building target) | 0.1 | ±0.5 m at d ≤100 m; ±(0.5 m + 0.0007d) for 100 m < d <1,200 m (—) | 2–10 Hz | UART-TTL; customizable | 5 | 200 | source 2026-11-12 | range ×6; weight ×0.17; shared interface: UART | |
| ERDI | LR1500E2 | 905 | 1.5 km | 4–1,500 m (Standard range; actual reach depends on target and environment.) | 4 | ±1 m (6 m ≤ D < 500 m); ±(0.5 m + 0.001D) (500 m ≤ D ≤ 1,500 m) (Whiteboard target, 90% reflectivity: 2.3 × 2.3 m for the first distance interval; 2.3 × 4.6 m for the second.) | 2–10 Hz (adaptive) | UART-TTL | 10 | 100 | erdi-lrf-drivers (Python, ROS 2), ErdiLRF (Arduino) | source 2026-11-12 | range ×7.5; weight ×0.33; shared interface: UART |
Missing a module? Add it in a pull request with the manufacturer source link.